{"product_id":"dpe-dst-triple-sense-gait-analysis-system-pressure-mapping-for-stairs-slope-walking","title":"DPE - DST Triple Sense Gait Analysis System | Pressure Mapping for Stairs, Slope \u0026 Walking","description":"\u003csection style=\"max-width: 900px; margin: 0 auto; font-family: 'DM Sans', Arial, sans-serif; line-height: 1.6; color: #1a1a1a;\"\u003e\n\u003cdiv style=\"position: relative; width: 100%; padding-bottom: 56.25%; height: 0; overflow: hidden; margin-bottom: 24px; border-radius: 8px;\"\u003e\u003ciframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: 0;\" title=\"DST Triple Sense — Product Video\" src=\"https:\/\/youtube.com\/embed\/SgssY6_vseo\"\u003e\n    \u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-size: 24px; font-weight: bold; margin: 0 0 20px 0;\"\u003eTriple Gait Analyzer\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 16px 0;\"\u003eThe \u003cstrong\u003eDST Triple Sense\u003c\/strong\u003e is a gait analysis system combining three rehabilitation modalities — flat-surface walking on 3-meter parallel bars, a height-adjustable staircase, and an angle-adjustable slope — within a single force-plate platform with pressure-mapping technology. It supports neurological, orthopedic, and geriatric rehab diagnosis and research.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 16px 0;\"\u003eCaptured metrics include right\/left and anterior\/posterior force distribution, center of pressure, foot angle, step length and time, stair height\/time, slope degree\/time, and 3-meter walk time. A built-in \u003cstrong\u003eRomberg Test\u003c\/strong\u003e logs sway area, sway velocity, and CoP displacement. Real-time visual and auditory biofeedback uses adjustable asymmetry thresholds, and raw pressure-matrix data exports for research.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/section\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cstyle\u003e\n  .feature-row{\n    display:grid;\n    grid-template-columns:1.1fr 1fr;\n    gap:48px;\n    align-items:center;\n    margin-bottom:36px;\n  }\n  .feature-row.reverse{\n    grid-template-columns:1fr 1.1fr;\n  }\n  .feature-row:last-of-type{\n    margin-bottom:0;\n  }\n  .feature-media{\n    border-radius:18px;\n    overflow:hidden;\n    height:260px;\n    width:100%;\n    position:relative;\n  }\n  .feature-media img,\n  .feature-media iframe,\n  .feature-media video{\n    width:100%;\n    height:100%;\n    display:block;\n    object-fit:cover;\n    border-radius:18px;\n    border:0;\n  }\n  .feature-copy p{\n    font-size:16px;\n    margin:0;\n    color:#555;\n  }\n  .feature-copy p strong{\n    color:#111;\n    font-weight:700;\n    font-size:20px;\n    display:block;\n    margin-bottom:10px;\n  }\n  .feature-copy p + p{\n    margin-top:10px;\n  }\n  .feature-copy ul{\n    margin:0;\n    padding-left:20px;\n    font-size:15px;\n    color:#555;\n  }\n  .feature-copy ul li{\n    margin-bottom:4px;\n  }\n  @media(max-width:900px){\n    .feature-row,.feature-row.reverse{\n      grid-template-columns:1fr;\n      gap:20px;\n    }\n    .feature-copy p,.feature-copy ul{\n      text-align:left;\n    }\n    .feature-media{\n      height:220px;\n    }\n  }\n\u003c\/style\u003e\n\u003csection style=\"max-width: 1200px; margin: 0 auto; padding: 40px 20px 0; background: #fff; font-family: Arial,sans-serif; line-height: 1.7;\"\u003e\n\u003cdiv class=\"feature-row\"\u003e\n\u003cdiv class=\"feature-media\"\u003e\u003ciframe src=\"https:\/\/youtube.com\/embed\/iCHwqy-1t3I\" title=\"DST Triple Sense — Analyzed Data\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eAnalyzed Data Includes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRight\/left force distribution\u003c\/li\u003e\n\u003cli\u003eAnterior\/posterior force distribution\u003c\/li\u003e\n\u003cli\u003eCenter of Pressure\u003c\/li\u003e\n\u003cli\u003eFeet angle\u003c\/li\u003e\n\u003cli\u003eStep length\u003c\/li\u003e\n\u003cli\u003eStep time\u003c\/li\u003e\n\u003cli\u003eStair usage — height and time\u003c\/li\u003e\n\u003cli\u003eSlope usage — degree and time\u003c\/li\u003e\n\u003cli\u003eParallel bars — 3-meter walk-time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-row reverse\"\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eBiofeedback\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe DST Triple Sense provides real-time visual and auditory biofeedback across stairs, slope, and parallel bars, letting clinicians target specific movement patterns and set custom asymmetry thresholds — patients hear a positive cue when performing within range and lose it when they deviate, keeping them motivated and self-correcting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-media\"\u003e\u003cvideo autoplay=\"autoplay\" muted=\"\" loop=\"loop\" playsinline=\"\"\u003e\n        \u003csource src=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/971de45966864870b742a41c65631312.mp4\" type=\"video\/mp4\"\u003e\u003c\/video\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cstyle\u003e\n  .feature-copy ul{\n    list-style-position:outside;\n    padding-left:24px;\n    margin:0 0 8px 0;\n  }\n  .feature-copy ul li{\n    line-height:1.3;\n    margin:0;\n  }\n  .feature-copy ul li h4{\n    display:inline;\n    margin:0;\n    font-size:22px;\n    font-weight:700;\n    color:#111;\n    line-height:1.3;\n  }\n  .feature-copy ul li::marker{\n    font-size:22px;\n    color:#111;\n  }\n  .feature-copy p{\n    margin:8px 0 20px 0;\n    font-size:15px;\n    color:#555;\n    line-height:1.6;\n  }\n  .feature-video{\n    width:100%;\n    max-width:1200px;\n    margin:0 auto 32px auto;\n    border-radius:18px;\n    overflow:hidden;\n    display:block;\n  }\n  .feature-video video{\n    width:100%;\n    height:auto;\n    display:block;\n    border-radius:18px;\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"feature-video\"\u003e\n  \u003cvideo autoplay muted loop playsinline\u003e\n    \u003csource src=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/29b9bea1e9604754be327486f67dcc3b.mp4\" type=\"video\/mp4\"\u003e\u003c\/video\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"feature-copy\"\u003e\n  \u003cul\u003e\n    \u003cli\u003e\u003ch4\u003eRomberg Test\u003c\/h4\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp\u003eThe DST Triple Sense enhances the Romberg balance assessment with pressure-mapping precision, capturing sway area, sway velocity, and right\/left and anterior\/posterior CoP movement range to detect stability changes early and reveal compensation patterns.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n  \u003cul\u003e\n    \u003cli\u003e\u003ch4\u003eAvailable in seven languages\u003c\/h4\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp\u003eEnglish, Spanish, French, German, Russian, Ukrainian, and Czech — the system generates per-session treatment reports and longitudinal progress tracking for rehab workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n  \u003cul\u003e\n    \u003cli\u003e\u003ch4\u003eDiagnosis\u003c\/h4\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp\u003eThe DST Triple Sense closes the gap between clinic and lab with evidence-based gait analysis across parallel bars, stairs, and slope — measuring weight distribution, step length and time, center of pressure, and foot loading to pinpoint impairment, build treatment plans, track progress, and flag fall risk, while strengthening insurer justification and reducing rehab cost and duration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n  \u003cul\u003e\n    \u003cli\u003e\u003ch4\u003eResearch\u003c\/h4\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp\u003eThe DST Triple Sense is the only system combining parallel bars, stairs, and slope with force-plate pressure mapping — capturing weight distribution, step length and time, center of pressure, and foot loading to pinpoint impairment, build treatment plans, track progress, and flag fall risk. It also unlocks research into stair-fall thresholds (responsible for 51% of elderly fall-related TBIs, 70% of home falls, and 10% of fatal fall accidents), movement-pattern correlations, and biofeedback-driven exercise comparisons.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial, sans-serif;margin-bottom:30px;\"\u003e\n  \u003ctr style=\"background-color:#000;color:#fff;\"\u003e\n    \u003cth colspan=\"2\" style=\"padding:12px;text-align:left;font-size:16px;\"\u003eDIMENSIONS\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eFlat walking surface\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e3 Meter (9.8 ft.)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eTotal \/ Handrails length\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e360 cm (142 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eTotal width\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e105 cm (42 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eStairs \/ slope width\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e65 cm (25.6 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eSlope angle range\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e0 to 26 degrees\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eStairs height\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e0 to 16.5 cm (0 to 6.5 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eHandrails height range\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e65 to 93 cm (25.6 to 36.6 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#000;color:#fff;\"\u003e\n    \u003cth colspan=\"2\" style=\"padding:12px;text-align:left;font-size:16px;\"\u003eCAPACITY \u0026amp; WEIGHT\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eCapacity (static)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e250 kg (551 lbs.)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eUnit weight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e374 kg (824 lbs.)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#000;color:#fff;\"\u003e\n    \u003cth colspan=\"2\" style=\"padding:12px;text-align:left;font-size:16px;\"\u003eTOUCHSCREEN MONITOR\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eOperating system\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003eWindows 10\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eScreen size\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e12\" to 15\"\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e110 to 230 AC with 12VDC transformer\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#000;color:#fff;\"\u003e\n    \u003cth colspan=\"2\" style=\"padding:12px;text-align:left;font-size:16px;\"\u003eSENSORS\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eSense system\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003eBy DPE Medical\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eSensor modules\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e9 modules\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eTotal sensors\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e13,122\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eSensor weight capacity\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003eUp to 5 kg per cm²\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#000;color:#fff;\"\u003e\n    \u003cth colspan=\"2\" style=\"padding:12px;text-align:left;font-size:16px;\"\u003eELECTRICAL\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eElectrical requirements\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e100 to 240V, 50\/60Hz, 4A max\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;text-align:left;width:40%;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e\u003cstrong\u003eOperating interval\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;text-align:left;vertical-align:top;word-break:break-word;hyphens:auto;\"\u003e2 min on \/ 18 min off\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DPE Medical","offers":[{"title":"Default Title","offer_id":59431079051345,"sku":"DPEDSTTriplesense","price":73900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/5882\/0177\/files\/DSTTripleSense12.png?v=1777409757","url":"https:\/\/morellimedical.com\/it\/products\/dpe-dst-triple-sense-gait-analysis-system-pressure-mapping-for-stairs-slope-walking","provider":"Morelli Medical","version":"1.0","type":"link"}