Price Match Guarantee. Flexible Financing. Fast & Free Shipping (Excl. May Apply) ⚕️

Now Available IN-STOCK HE5000 READY TO SHIP!! Call us now at 866-338-2838

Early Black Friday Sale

MM15

Up to 15% Off on Selected HBOT Products

Tanita  |  SKU: DC-430U

Tanita DC-430U Body Composition Analyzer, Remote Display Version with Built-In Printer, 600 lb


$4,299.99
Talk to an Expert Call 866-338-2838

Authorized Tanita Dealer

3-Year Limited Warranty

  • US-Based Support
  • Pioneer in Body-Fat Measurement
  • 100+ Years of Business Heritage
  • Multiple International Design Awards
  • ISO 9001 & ISO 13485 Certified
In-stock items ship within 3 business days, while out-of-stock items have a 100–120-day lead time.


Free Shipping & Price Match Guarantee

Enjoy Free Shipping on orders over $200 and the Lowest Prices Online guaranteed!

Find a lower price? Call (866) 338-2838 and we'll match it! (Some exclusions may apply.

See our Price Match Guarantee Policy for more information)

What is your Return Policy?

We want you to be fully satisfied with your purchase. If you need to cancel an order before it ships, contact us at info@morellimedical.com or 866-338-2838 for a full refund.

For most products, we offer a 30-day return policy from the date of delivery, excluding Macy-Pan, OxyRevo, ShowerBuddy, Journey *selected products*, OMI and EZ Carrier, which are final sale.

The customer is responsible for all return costs, including a 25% restocking fee, return shipping, and any applicable additional charges.

Click Learn more to read our Detailed Return Policy.

What Financing Options are Available?

Klarna – Buy now, pay later with Klarna’s flexible payment plans. Split your purchase into interest-free installments or choose extended payment options.

Affirm – Get the products you want now and pay over time with Affirm. Choose monthly payments with no hidden fees or surprises.

Shop Pay – Use Shop Pay for easy installment payments at checkout. Pay in 4 interest-free payments, making it simple and convenient to spread out your purchase

APPROVE Financing - For businesses, APPROVE offers fast and flexible equipment financing tailored to your needs. Apply in just 60 seconds and get matched with top lenders, no credit score impact to apply. Apply Now!

Message us for other business financing if interested!

Warranty, Shipping, and Returns

Warranty ▾
Warranty basics

TANITA products are warranted to the original purchaser to be free from manufacturer defects under normal use. The warranty is backed by Tanita Corporation of America, the exclusive U.S. distributor, and applies only to products purchased from TANITA.com or an authorized TANITA dealer. Proof of purchase is required for every claim — keep your order confirmation or receipt, and consider registering your product with TANITA at tanita.com.

  • Use the right scale for the setting. Consumer scales and body composition monitors are designed for personal use only; TANITA reserves the right to void the warranty if a consumer model is used in a commercial or professional environment. Clinics, gyms and practices should use TANITA's professional analyzers.
  • Voids the warranty: tampering or mistreatment, and any defect related to servicing or parts not supplied by TANITA.
  • Not covered: normal wear of parts, and damage caused by negligent use or misuse, use on improper voltage or current, use contrary to the operating instructions, abuse or tampering, damage in transit, unauthorized repair or alterations, or natural disasters such as fire, flood, hurricanes and tornadoes.
  • Dealers and retailers cannot alter, modify or extend the terms of TANITA's warranty.
Warranty length

Coverage runs from the date of purchase and varies by product line — the exact term for your model is printed in its user manual.

  • Professional body composition analyzers (MC-980U, MC-780U, MC-580, DC-430U, DC-240, TBF-400, DC-13C and similar): 3 to 5 years, depending on the model — for example, the DC-430U carries a 4-year warranty. Where the manual specifies it, the AC adapter is covered for 1 year.
  • Consumer bathroom scales and at-home body composition monitors: 3 years.
  • Kitchen and mini scales: 1 year.
Remedies and costs

If a covered defect is confirmed, TANITA's obligation is limited to repairing the product (labor plus parts) or, at TANITA's option, replacing it with an equivalent model. TANITA is not liable for incidental or consequential damages, and any recovery is capped at the purchase price of the product.

  • A Return Merchandise Authorization (RMA) is required before anything is sent in; shipments arriving without an RMA number are refused.
  • You pay the shipping to TANITA's service center and bear the risk of loss in transit, so insure the package and use a carrier that provides proof of delivery (UPS or FedEx). TANITA ships the repaired or replacement unit back to you at its expense via UPS.
  • All defective items must be confirmed defective by the factory before a repair, replacement or credit is issued.
  • Out-of-warranty repairs are available for a labor charge plus the cost of parts, quoted after evaluation.

To start a warranty claim, contact Morelli Medical at info@morellimedical.com or (866) 338-2838 with your order number, the model and serial number, and a description of the fault, and we will obtain the RMA and coordinate with TANITA on your behalf.

Returns ▾
Return Policy

Returns received within 30 days of the original delivery date are eligible for a full credit of the product price; the original shipping fee is non-refundable. Every return requires an RMA number issued before the item ships back — returns arriving without one are refused.

  • Items must be in their original factory packaging and undamaged, with all parts and manuals included.
  • When requesting an RMA, have your invoice number, order date, reason for return, the action you'd like (replacement, repair or credit), and whether the box has been opened or is still manufacturer-sealed.
  • You are responsible for shipping charges to TANITA's warehouse and for the risk of loss or damage in transit on all returns, exchanges and replacements — please fully insure the shipment and use a carrier with proof of delivery. Exchanged or replaced products are shipped back to you at TANITA's expense via UPS.
  • Using a product outside the manufacturer's intended use (for example, a consumer scale in a professional setting) voids the warranty and may affect return eligibility.

To request an RMA, contact Morelli Medical at info@morellimedical.com or (866) 338-2838 with your order number.

Refunds

Approved returns are credited to the original payment method once the product has been received and inspected. Items returned as defective must first be confirmed defective by the factory before any credit is issued. Original shipping charges are not refunded, and if a delivery is refused or the carrier is unable to deliver, any additional shipping expense is the customer's responsibility.

Shipping ▾
Shipping and claims overview

TANITA scales and analyzers ship by parcel carrier (UPS) within the United States. In-stock products typically ship within 1–3 business days of your order, and you'll receive tracking by email once the package is on its way. Professional analyzers with columns ship in larger cartons but still travel by parcel, not freight.

  • Please make sure someone is available to receive the package. If a delivery is refused or the carrier cannot deliver for any reason, the customer is responsible for any additional shipping expense.
  • Damage that occurs in transit is excluded from TANITA's product warranty and is handled as a shipping claim instead, so inspect your order as soon as it arrives.
Filing a claim

Check the carton and the product as soon as it is delivered, before setting the scale up.

  • If the box is visibly crushed, punctured or wet, note the damage with the driver or on the carrier's delivery record, or refuse the delivery.
  • Photograph the damage to the packaging and the product, and keep all original packaging and packing materials until the claim is resolved.
  • Contact Morelli Medical right away at info@morellimedical.com or (866) 338-2838 with your order number, photos and a description of the damage. We'll file the carrier claim and obtain an RMA from TANITA for a replacement.

Products that arrive defective (rather than damaged) follow the same RMA process; TANITA will confirm the defect and repair or replace the unit under warranty.

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa

Shop with confidence - your transactions are SSL-encrypted and your payment details are securely transmitted.

We never store or have access to your credit card information.

Model Comparison

Tanita

Tanita DC-430U Body Composition Analyzer, Remote Display Version with Built-In Printer, 600 lb

$4,299.99

Tanita DC-430U Body Composition Analyzer, Remote Display Version with Built-In Printer

The Tanita DC-430U is a foot-to-foot body composition analyzer in a two-piece remote display version: a weighing platform plus a separate control box. It measures impedance between both feet at 6.25 kHz and 50 kHz through four stainless steel electrodes. The 14.1″ × 14.1″ × 3.7″ platform weighs up to 600 lb (270 kg) in 0.2 lb (0.1 kg) steps.

Results include weight, body fat percentage and mass, fat-free mass, muscle mass and score, visceral fat rating, total body water, BMR, metabolic age, physique rating, bone mass, BMI, resistance, reactance and phase angle. Wrestling Mode calculates minimum wrestling weight for high school and collegiate wrestlers, and users aged 5 to 17 receive body fat percentage only.

The LCD control box works with a built-in printer that auto-cuts and prints in English, French or Spanish. Data exports as CSV via USB Type B or RS-232C (one at a time) and to SD/SDHC cards. Power is a 100–240V AC adapter, and the set weighs 15.4 lb.

Notice: Do not use on persons with a pacemaker or other implanted electronic medical device. Electrodes are stainless steel; do not use on persons with metal allergies. Keep away from flammable gases and oxygen-rich environments.

Features

Specifications

GENERAL
Model TANITA DC-430U Multi-Frequency Total Body Composition Analyzer (remote display version, no column)
Manufacturer TANITA
Product Type Professional full-body composition analyzer with separate display/printer control box
Applications Weight loss and fitness programs, clinics, hospitals, research institutes
Color Dark Gray
Age Range 5 to 99 years (most outputs and Athletic mode 18 to 99; ages 17 and under show body fat % only)
Body Types Standard, Athletic
Height Input 3 ft 0.0 in to 7 ft 11.5 in (90.0 to 249.9 cm)
SPECIAL MODES
Kids Mode Exclusive children's body fat analysis and judgment mode (ages 5 to 17)
Wrestler Mode Calculates Minimum Wrestling Weight at 7% (high school male) or 5% (collegiate male) minimum body fat; off by default
Scale Mode Weight-only measurement
WEIGHING
Weight Range 4 to 600 lb (2 to 270 kg), including preset tare
Increment 0.2 lb (0.1 kg)
Accuracy at First Calibration ±0.4 lb (±0.2 kg)
Weighing System Strain gauge load cell
Clothes Weight (Tare) 0.0 to 20.0 lb (0.2 lb increments)
BODY COMPOSITION ANALYSIS
Method Dual-frequency, 4-electrode foot-to-foot bioelectrical impedance analysis
Frequencies 6.25 kHz / 50 kHz
Measurement Current Up to 90 µA
Electrodes Stainless steel foot pads
Impedance Range 150.0 to 1,000.0 Ω (0.1 Ω increments), ±2% at first calibration
Measurement Time Under 30 seconds
Measurements 15 full-body measurements: weight, body fat %, fat mass, fat-free mass, muscle mass, total body water, total body water %, bone mass, basal metabolic rate, metabolic age, visceral fat rating, physique rating, BMI, ideal body weight, degree of obesity
Additional Outputs Desirable range for fat % and fat mass, target body fat %, bioelectrical data (resistance, reactance)
Output Ranges Body fat 3.0% to 75.0%; visceral fat rating 1 to 59; physique rating 1 to 9; metabolic age 12 to 90
Target Body Fat 4% to 55% (1% increments)
ID Number Up to 16 digits, with optional automatic count-up
DISPLAY, PRINTING & DATA
Display LCD on remote control box (can sit on a desk while platform stays on the floor)
Printer Built-in thermal printer with auto-cut; full or short printouts in English, French, or Spanish
Interfaces USB Type B, RS-232C (one at a time), SD card; CSV output for EMR use
Data Storage SD/SDHC card (SDXC not supported); about 10,000 weight-only results per 2 GB card
Software TANITA PRO® Software (sold separately) for remote programming, analysis, and graphing
POWER & OPERATING CONDITIONS
Power Source AC adapter, input 100 to 240V AC (50/60 Hz), output 12V DC, 25 VA
Operating Temperature 41 to 95°F (5 to 35°C)
Relative Humidity 30% to 80% (non-condensing)
Maximum Altitude 6,500 ft (2,000 m)
PHYSICAL
Product Weight 15.4 lb (7 kg) per manual; Tanita US header lists 15.2 lb
Platform Size 360 × 360 × 94 mm (14 × 14 × 4 in)
Feet Adjustable feet for leveling
INCLUDED
In the Box Platform, control box with printer, AC adapter, 120V AC cord, printer paper, instruction manual (CD-ROM)
Not Included Column kit, USB and RS-232 cables, SD card, TANITA PRO® Software
Optional Accessories TANITA PRO® Software, C300 Carry Bag, HR-200 Wall Mounted Height Rod, USB Cable Type A-B
SAFETY
Contraindications Not for use by people with pacemakers or other electrical medical implants

What’s Included

View product