{"product_id":"bionet-cardiotouch-3000-premium-interpretive-12-channel-ecg-ekg-machine","title":"Bionet CardioTouch 3000 Premium Interpretive 12-Channel ECG EKG Machine","description":"\u003cdiv style=\"position: relative; width: 100%; padding-top: 56.25%; margin: 20px 0;\"\u003e\u003ciframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: 0;\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/mkjSJjiE_f0?si=oUMjk7oJrjzBNkXZ\"\u003e\n  \u003c\/iframe\u003e\u003c\/div\u003e\n\u003ch4 data-start=\"180\" data-end=\"509\"\u003ePremium 12-Channel ECG Diagnostics Made Simple\u003c\/h4\u003e\n\u003cp data-end=\"558\" data-start=\"183\"\u003eThe \u003cstrong data-end=\"207\" data-start=\"187\"\u003eCardioTouch 3000\u003c\/strong\u003e is a \u003cstrong data-end=\"264\" data-start=\"213\"\u003epremium interpretive 12-channel ECG EKG machine\u003c\/strong\u003e designed to deliver \u003cstrong data-end=\"325\" data-start=\"285\"\u003ehigh-performance cardiac diagnostics\u003c\/strong\u003e with exceptional ease of use. Ideal for \u003cstrong data-end=\"387\" data-start=\"366\"\u003eprivate practices\u003c\/strong\u003e, \u003cstrong data-end=\"414\" data-start=\"389\"\u003eemergency departments\u003c\/strong\u003e, and \u003cstrong data-end=\"445\" data-start=\"420\"\u003ehospital environments\u003c\/strong\u003e, it combines \u003cstrong data-end=\"480\" data-start=\"459\"\u003eclinical accuracy\u003c\/strong\u003e with an \u003cstrong data-end=\"515\" data-start=\"489\"\u003eintuitive ECG workflow\u003c\/strong\u003e to support fast and confident evaluations.\u003c\/p\u003e\n\u003cp data-end=\"979\" data-start=\"560\"\u003eFeaturing a \u003cstrong data-end=\"608\" data-start=\"572\"\u003e4.3 inch touchscreen ECG display\u003c\/strong\u003e with \u003cstrong data-end=\"632\" data-start=\"614\"\u003erotary control\u003c\/strong\u003e, the CardioTouch 3000 enables simple operation through \u003cstrong data-end=\"722\" data-start=\"688\"\u003eone-touch AUTO ECG acquisition\u003c\/strong\u003e. The system completes \u003cstrong data-end=\"797\" data-start=\"745\"\u003eECG recording, data storage, and A4 ECG printout\u003c\/strong\u003e in approximately three seconds. Its \u003cstrong data-end=\"866\" data-start=\"834\"\u003ehigh-speed ECG sampling rate\u003c\/strong\u003e ensures precise waveform capture, while \u003cstrong data-end=\"940\" data-start=\"907\"\u003efull-size 12-lead ECG reports\u003c\/strong\u003e improve readability and documentation.\u003c\/p\u003e\n\u003cp data-end=\"1405\" data-start=\"981\"\u003eWith over \u003cstrong data-end=\"1028\" data-start=\"991\"\u003e120 ECG interpretation algorithms\u003c\/strong\u003e, a \u003cstrong data-end=\"1068\" data-start=\"1032\"\u003erechargeable lithium-ion battery\u003c\/strong\u003e, and \u003cstrong data-end=\"1113\" data-start=\"1074\"\u003ewired and wireless ECG connectivity\u003c\/strong\u003e, the CardioTouch 3000 integrates seamlessly into modern clinical settings. The included \u003cstrong data-end=\"1238\" data-start=\"1202\"\u003eBMS-Plus ECG management software\u003c\/strong\u003e allows \u003cstrong data-end=\"1298\" data-start=\"1246\"\u003eECG data transfer to Windows PCs and EMR systems\u003c\/strong\u003e, supporting multiple formats including \u003cstrong data-end=\"1360\" data-start=\"1338\"\u003eECG, JPEG, and PDF\u003c\/strong\u003e for efficient \u003cstrong data-end=\"1404\" data-start=\"1375\"\u003epatient record management\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/5882\/0177\/files\/Bionet-Medical-equipment-promo-long-banner.jpg?v=1769714885\"\u003e\u003c\/div\u003e\n\u003ch3 data-start=\"833\" data-end=\"1185\"\u003eFeatures\u003c\/h3\u003e\n\u003cstyle\u003e\n  .feature-row{\n    display:grid;\n    grid-template-columns:1.1fr 1fr;\n    gap:48px;\n    align-items:center;\n    margin-bottom:36px;\n  }\n  .feature-row.reverse{\n    grid-template-columns:1fr 1.1fr;\n  }\n  .feature-row:last-of-type{\n    margin-bottom:0;\n  }\n\n  .feature-media{\n    border-radius:18px;\n    overflow:hidden;\n    height:260px;\n    width:100%;\n  }\n  .feature-media img{\n    width:100%;\n    height:100%;\n    display:block;\n    object-fit:cover;\n    border-radius:18px;\n  }\n\n  .feature-copy p{\n    font-size:16px;\n    margin:0;\n    color:#555;\n  }\n  .feature-copy p strong{\n    color:#111;\n    font-weight:700;\n  }\n  .feature-copy p + p{\n    margin-top:10px;\n  }\n\n  @media(max-width:900px){\n    .feature-row,.feature-row.reverse{\n      grid-template-columns:1fr;\n      gap:20px;\n    }\n    .feature-copy p{\n      text-align:center;\n    }\n    .feature-media{\n      height:220px;\n    }\n  }\n\u003c\/style\u003e\n\u003csection style=\"max-width: 1200px; margin: 0 auto; padding: 40px 20px 0; background: #fff; font-family: Arial,sans-serif; line-height: 1.7;\"\u003e\u003c!-- FEATURE 1 --\u003e\n\u003cdiv class=\"feature-row\"\u003e\n\u003cdiv class=\"feature-media\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/5882\/0177\/files\/CardioTouch-3000-Bionet-interpretive-12-channel-electrocardiogram-ECG-EKG-machine_Up-1450x1450_734bed57-21f9-4344-81e4-75a4712efea5.webp?v=1769718378\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n\u003cp data-end=\"221\" data-start=\"186\"\u003e\u003cstrong data-end=\"221\" data-start=\"190\"\u003eSimultaneous 12-Channel ECG\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"328\" data-start=\"222\"\u003eCaptures all 12 leads at the same time for accurate resting ECG recordings and reliable clinical analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FEATURE 2 --\u003e\n\u003cdiv class=\"feature-row reverse\"\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n\u003cp data-end=\"370\" data-start=\"335\"\u003e\u003cstrong data-end=\"370\" data-start=\"339\"\u003eAdvanced ECG Interpretation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"487\" data-start=\"371\"\u003eBuilt-in interpretation program delivers automated diagnostic results to support faster, more confident evaluations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-media\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/5882\/0177\/files\/ecg.png?v=1769719329\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FEATURE 3 --\u003e\n\u003cdiv class=\"feature-row\"\u003e\n\u003cdiv class=\"feature-media\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/5882\/0177\/files\/CardioTouch-3000-Bionet-interpretive-12-channel-electrocardiogram-ECG-EKG-machine_left-1450x1450_7fc6cd4c-78d8-4ea3-b2c9-e7e53b6cdca7.webp?v=1769718566\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n\u003cp data-end=\"521\" data-start=\"494\"\u003e\u003cstrong data-end=\"521\" data-start=\"498\"\u003eOne-Touch Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"604\" data-start=\"522\"\u003eSimple controls allow instant monitoring and recording with a single button press.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FEATURE 4 --\u003e\n\u003cdiv class=\"feature-row reverse\"\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n\u003cp data-end=\"640\" data-start=\"611\"\u003e\u003cstrong data-end=\"640\" data-start=\"615\"\u003eFull-Size A4 Printing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"749\" data-start=\"641\"\u003eSupports multiple print formats on full-size A4 paper, improving readability and making chart filing easier.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-media\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/5882\/0177\/files\/CardioCare2000_Bionet_ECG_EKG_print-1450x1450_e5f78097-6e33-4d0a-8f3c-01a07c1dc726.webp?v=1769710687\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FEATURE 5 --\u003e\n\u003cdiv class=\"feature-row\"\u003e\n\u003cdiv class=\"feature-media\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0570\/5882\/0177\/files\/1-4-1450x1450.webp?v=1769710738\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"feature-copy\"\u003e\n\u003cp style=\"text-align: center;\" data-end=\"794\" data-start=\"756\"\u003e\u003cstrong data-end=\"794\" data-start=\"760\"\u003eBMS Plus Software Connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"903\" data-start=\"795\"\u003eTransfers digital ECG data to Windows-based PCs for storage, review, and seamless patient record management.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003ch3 data-start=\"833\" data-end=\"1185\"\u003eSpecifications\u003c\/h3\u003e\n\u003c!-- final table here --\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: Arial, sans-serif; margin-bottom: 30px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-size: 16px;\" colspan=\"2\"\u003eECG PERFORMANCE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eECG Leads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eSimultaneous 10 leads resting ECG (12 channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eRecording Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e3CH+1RHY, 3CH+3RHY, 6CH+1RHY, 12CH, 1CH long time (1 min), beat report\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e2.5, 5, 10, 20, auto (I–aVF: 10, V1–V6: 5) mm\/mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003ePrint Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e5, 12.5, 25, 50, 100 mm\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eAnalysis: 500 sample\/sec\u003cbr\u003eDigital: 8,000 sample\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eFilters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eAC (50\/60 Hz, -20 dB or better)\u003cbr\u003eMuscle (25–35 Hz, -3 dB or better)\u003cbr\u003eBaseline drift (off, 0.05, 0.1, 0.2 Hz, -3 dB or better)\u003cbr\u003eLow pass (off, 40 Hz, 100 Hz, 150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-size: 16px;\" colspan=\"2\"\u003eDISPLAY AND INTERFACE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e272 × 480 pixels, 4.3\" color TFT display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eScreen Info\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e12 channels preview, ID, HR, gain, speed, power status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eUser Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eTouch screen, rotary push-knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-size: 16px;\" colspan=\"2\"\u003eOUTPUT AND FILES\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eExport Formats\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eECG, XML, PDF, JPEG, MFER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eRecorder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eThermal print head, roll paper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003ePaper Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eA4 or Letter, 215 mm (8.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003ePaper Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eA4 297 mm (11.7\"), Letter 279 mm (11\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e8 dot\/mm (0.125 mm pitch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-size: 16px;\" colspan=\"2\"\u003ePATIENT DATA AND MEASUREMENTS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003ePatient Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eID, name, age, gender, height, weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eHeart Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e30–300 bpm (±3 bpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eMeasurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003ePR, QRS, QT\/QTc, P–R–T axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eECG Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eInternal storage for 200 ECGs (built-in memory), external memory available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-size: 16px;\" colspan=\"2\"\u003eELECTRICAL AND SIGNAL\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eInternal Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e20 uV (p-p) max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eMore than 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eGreater than 105 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eDC Offset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e≥ ±400 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eLeakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u0026lt; 10 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e0.05–150 Hz (within -3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eIsolated, defibrillation and ESU protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eSignal Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003ePacemaker pulse detection, lead fault detection, signal saturation detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-size: 16px;\" colspan=\"2\"\u003ePOWER AND CONNECTIVITY\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e100–240 Vac, 1.5–0.75 A, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e15 Vdc, 4.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eReplaceable and rechargeable lithium ion, 11.1 V, 2600 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e6 hours normal use (without recording, 200 ECGs) with 12 channel, charge time 3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eLAN, USB, WiFi (option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-size: 16px;\" colspan=\"2\"\u003eSAFETY AND ENVIRONMENT\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eSafety Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eClass I, Type CF (defibrillation-proof applied part)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e5–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e10–90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eAtmospheric Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e70–106 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-size: 16px;\" colspan=\"2\"\u003ePHYSICAL\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e290 mm (W) × 300 mm (D) × 97.5 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; text-align: left; width: 40%; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; text-align: left; vertical-align: top; word-break: break-word; hyphens: auto;\"\u003eApproximately 3.5 kg (main body)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"50\" data-end=\"78\"\u003eCardioTouch 3000 main unit\u003c\/li\u003e\n\u003cli data-start=\"81\" data-end=\"108\"\u003e10-lead ECG patient cable\u003c\/li\u003e\n\u003cli data-start=\"111\" data-end=\"128\"\u003eAlligator clips\u003c\/li\u003e\n\u003cli data-start=\"131\" data-end=\"143\"\u003eElectrodes\u003c\/li\u003e\n\u003cli data-start=\"146\" data-end=\"164\"\u003eMedi-Graph paper\u003c\/li\u003e\n\u003cli data-start=\"167\" data-end=\"194\"\u003eHospital-grade power cord\u003c\/li\u003e\n\u003cli data-start=\"197\" data-end=\"215\"\u003eOperation manual\u003c\/li\u003e\n\u003cli data-start=\"218\" data-end=\"242\"\u003eDiagnostics guide book\u003c\/li\u003e\n\u003cli data-start=\"245\" data-end=\"268\"\u003eQuick reference guide\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bionet","offers":[{"title":"Default Title","offer_id":59033589973073,"sku":"ECG-3000(N)","price":1199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0570\/5882\/0177\/files\/CardioTouch-3000-Bionet-interpretive-12-channel-electrocardiogram-ECG-EKG-machine_left-1450x1450.webp?v=1769717409","url":"https:\/\/morellimedical.com\/fr\/products\/bionet-cardiotouch-3000-premium-interpretive-12-channel-ecg-ekg-machine","provider":"Morelli Medical","version":"1.0","type":"link"}