InhaleH2 Hydrogen Inhalation Unit, Adjustable 0–4% FiH2, 12 L/min, SPE-PEM

Authorized InhaleH₂ Dealer
3-Year Limited Warranty
- US-Based Support
- 7 Years of Research & Development
- Patent-Pending Technology
- H2HUBB Seal of Approval
- 2026 Canadian SR&ED Recognition
InhaleH2 Hydrogen Inhalation Unit, Adjustable 0–4% FiH2, 12 L/min, SPE-PEM - 110V - USA Standard Plug est en rupture de stock et sera expédié dès qu’il sera de retour en stock.
Free Shipping & Price Match Guarantee
Free Shipping & Price Match Guarantee
Enjoy Free Shipping on orders over $200 and the Lowest Prices Online guaranteed!
Find a lower price? Call (866) 338-2838 and we'll match it! (Some exclusions may apply.
See our Price Match Guarantee Policy for more information)
What is your Return Policy?
What is your Return Policy?
We want you to be fully satisfied with your purchase. If you need to cancel an order before it ships, contact us at info@morellimedical.com or 866-338-2838 for a full refund.
For most products, we offer a 30-day return policy from the date of delivery, excluding Macy-Pan, OxyRevo, ShowerBuddy, Journey *selected products*, OMI and EZ Carrier, which are final sale.
The customer is responsible for all return costs, including a 25% restocking fee, return shipping, and any applicable additional charges.
Click Learn more to read our Detailed Return Policy.
What Financing Options are Available?
What Financing Options are Available?
Klarna – Buy now, pay later with Klarna’s flexible payment plans. Split your purchase into interest-free installments or choose extended payment options.
Affirm – Get the products you want now and pay over time with Affirm. Choose monthly payments with no hidden fees or surprises.
Shop Pay – Use Shop Pay for easy installment payments at checkout. Pay in 4 interest-free payments, making it simple and convenient to spread out your purchase
APPROVE Financing - For businesses, APPROVE offers fast and flexible equipment financing tailored to your needs. Apply in just 60 seconds and get matched with top lenders, no credit score impact to apply. Apply Now!
Message us for other business financing if interested!
Warranty, Shipping, and Returns
Warranty ▾
Every InhaleH₂ Hydrogen Inhalation System includes a three-year manufacturer warranty covering workmanship and assembly quality. Keep your order confirmation as proof of purchase. The warranty does not cover damage resulting from misuse or improper operation, use of any liquid other than distilled water, or unauthorized repairs or modifications — so the care rules below matter.
- Distilled water only. The tank must be filled with distilled water with Total Dissolved Solids (TDS) below 5 ppm. Tap, filtered, bottled or spring water voids the warranty; the unit's built-in purity sensor will also stop a session if it detects contaminated water.
- Let it warm up before first use. Allow the unit to sit at room temperature for at least 8 hours after delivery. Shipping in cold weather can freeze the PEM electrolyzer and water lines, and running the machine before it has warmed up can seriously damage internal components.
- Keep the tank wet. Always keep water in the tank, even when the machine is not in use, so the PEM (proton exchange membrane) stays hydrated. A dried-out PEM reduces performance and service life.
- Operate within range. Keep the machine in a cool, dry spot between 60–80°F (15–26°C), out of direct sunlight and high humidity, on a stable flat surface, and away from open flames.
- Follow the maintenance schedule. Replace the HEPA filter every 6 months (sooner if visibly dirty), drain and refill the water every 30–60 days, and clean the mask and breathing bag with mild soap and water as needed.
- Repairs beyond the procedures in InhaleH₂'s Supplemental Service Manual should only be performed by the manufacturer. Opening or modifying the unit outside those instructions voids coverage.
- InhaleH₂ inhalation unit: 3 years from the date of purchase, covering workmanship and assembly quality.
- Consumables and wear items — HEPA filters, silicone face and nose masks, breather bag and hoses — are maintenance parts expected to be replaced over time and are not covered for normal wear. Replacement parts are available from the manufacturer.
Connecting the unit to Wi-Fi is strongly recommended: firmware updates resolve error messages and improve performance, and support will ask you to confirm the latest firmware is installed before troubleshooting a fault.
If a covered workmanship or assembly defect occurs within the warranty period, InhaleH₂ will repair the unit or replace the affected components. Many faults — a stopped ventilation fan, trapped air in the water line, a low water or purity warning, or a humidity-triggered hydrogen sensor alert — can be resolved at home using the manual's troubleshooting steps and the Supplemental Service Manual, and support will walk you through them first.
- Report the issue before sending anything in: describe the error message shown on the Smart Knob, confirm the firmware is current, and have your order number ready.
- If a return to the manufacturer is required, drain the tank completely before packing and ship the unit in its original packaging. Shipping arrangements and costs for warranty service are confirmed by InhaleH₂ at the time the claim is approved.
- Damage caused by excluded conditions — non-distilled water, running the unit while frozen, or unauthorized repairs — is not covered; repairs in those cases are quoted after evaluation.
To start a warranty claim, contact Morelli Medical at info@morellimedical.com or (866) 338-2838 with your order number, a description of the problem and any error message displayed, and we will coordinate with InhaleH₂ support on your behalf. You can also reach InhaleH₂ directly at support@inhaleh2.com or 855-291-2422.
Returns ▾
The InhaleH₂ may be returned within 30 calendar days of delivery, provided it is in new, unused and undamaged condition with all original packaging, accessories, masks, hoses and manuals. Because the unit is a hydrogen generator with a sealed water system, "unused" means the tank has not been filled and the machine has not been run — a unit that has been operated cannot be resold as new and is not eligible for a change-of-mind return.
- Return requests must be submitted and approved before anything is shipped back; unauthorized returns may be refused.
- Returned units are inspected on receipt. Products that don't meet the conditions above may be refused or receive a reduced refund reflecting the loss in value.
- Original shipping charges are non-refundable and the customer pays return shipping, unless the return is due to our error or the product arrived damaged or defective. If we provide a prepaid label, its cost may be deducted from the refund.
- Orders cancelled before processing receive a full refund; orders over $5,000 that are cancelled after processing are subject to a 5% cancellation fee.
To request a return, contact Morelli Medical at info@morellimedical.com or (866) 338-2838 with your order number.
Once an approved return has been received and inspected and confirmed to be in its original, unused condition, the product's purchase price is refunded to the original payment method and you'll receive an email confirmation. Refused or undeliverable shipments are not treated as standard returns — outbound and return shipping costs are deducted from the refund. Units that fail after use are handled under the manufacturer's three-year warranty rather than as a return.
Shipping ▾
The InhaleH₂ ships free by parcel carrier within the United States. The unit is stocked and ready to ship, and the manufacturer keeps you updated by email at every stage, from confirmation through delivery. The packed unit weighs about 27 lb (12.25 kg) and measures 21.3 × 16.1 × 9.3 in, so it arrives as a single box — no freight or signature appointment required.
- Choose the correct voltage at checkout — 110V (US standard plug) or 220V (international plug). The voltage is printed next to the power switch, and running the unit on the wrong voltage can cause damage.
- After delivery, let the unit rest at room temperature for at least 8 hours before the first session, especially in cold weather, to protect the electrolyzer and water lines.
- Water in the lines may shift during transit and trap air. If the "Water Not Flowing" message appears, use the included water dropper to push water into the fill hole until bubbles stop — this is a normal post-shipping step, not a fault.
Inspect the carton and the unit as soon as it arrives, before filling the tank.
- Note any visible damage to the box when accepting the delivery, and refuse it if the carton is crushed or punctured.
- Photograph the packaging and any damage to the unit, masks or accessories, and keep all packing materials.
- Report transit damage, a defective unit or missing accessories within 48 hours of delivery to Morelli Medical at info@morellimedical.com or (866) 338-2838 with your order number and photos. Damaged, defective or incorrect items are replaced at no cost to you.
Damage discovered after the unit has been used is handled under the InhaleH₂ three-year warranty rather than as a shipping claim.
Payment & Security
Payment methods
Shop with confidence - your transactions are SSL-encrypted and your payment details are securely transmitted.
We never store or have access to your credit card information.